Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 107
Chapter 9
Optical data
Protective field
height
Protective field width 0 ... 6 m/2,5 ... 19 m
Beam gap
Resolution variants
Beam diameter
Wave length (typical) 950 nm
Electrical data
Supply voltage U
B
Power consumption,
sender
Power consumption,
receiver
Self-test time (of
safety-related func-
tions such as OSSD
and optical link)
Synchronisation
Max. response time
Connecting cable
Outputs OSSD 1 and
OSSD 2 (max. cable
length 60 m; the
measurements relate
to connection a the
device connector)
Table 9-1: Data sheet C 2000, M 2000 and M 2000-A/P
*) Upper and lower limit values of voltage supply must not be infringed.
**) The length of the connecting cable is limited, because wire resistance max. 1.1 Ω.
***) The outputs are tested cyclically in the active state (brief switch to LOW). When selecting the
downstream control elements ensure that the test pulses do not result in a shut-off within the above
parameters.
8008684/YJC8/2015-03-30
2 7 8
8 008 684/RI57/2007-11-28

Technical Data

9 9 9 9 9
Technical Data
C 2000
150 ... 1200 mm
(housing 34 x 29 mm)
1350 ... 1800 mm
(housing 40 x 48 mm)
20 (protective field height
max. 1200 mm)/30/40 mm
C 2000
24 V DC ± 20 % (refer to information on voltage supply from section 2.2.1!)
5 % ripple *)
Max. 6.2 W
Max. 8 W
3 s
(The total test duration incl. internal data memory is 23 minutes.)
Optical
7 ... 34 ms
(see rating field)
2
0.25 mm
(connector M 12), 15 m or 1 mm
PNP monitored and short-circuit-proof
Switching current I
= 500 mA
max
Switching voltage U
min = U
high
iInductive switching power P
Leakage current in case of error < 190 µA
Test pulse data: Test pulse width 240 µs ± 23%, Test pulse rate 28 ms ± 6 ms ***)
Residual current at signal level"0" I = 0 mA, max. capacitive load 2,2 µF
Multibeam Photoelectric Safety Switch M 2000
M 2000
To 1400 mm
0 ... 25 m/0 ... 70 m
(with range toggling)
300, 400, 500 mm
116, 170 mm
13 mm/23 mm (70 m)
M 2000
3.7 W
5 W
8 ms
2
(Hirschmann connector), 60 m **)
– 2,25 V at 500 mA, U
B
= 0.8 W (see Fig. 9-1)
max ind
© SICK AG • Safety Systems • Germany • All rights reserved
Operating Instructions
Safety Light Curtain C 2000
M 2000-A/P
0 ... 6 m
500 mm
13 mm
M 2000-A/P
7.5 W
7 ms
= 1 V
low max

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M2000