NS7 / V7 CALIBRATION
If you load new firmware to the NS7 / V7, or if you ever experience problems with your knobs or faders (a very rare occurrence), the
NS7 / V7 can be recalibrated. Follow these instructions to calibrate the unit.
IMPORTANT NOTES:
When setting the knobs and faders during calibration, set the faders last (to ensure they don't
accidentally move during adjustment).
When setting the knobs and faders, be sure they are all set at their endpoints. Slight inaccuracies
could result in an incorrect calibration.
The MIC / AUX GAIN, BASS, and TREBLE knobs are analog controls and therefore not part of the
calibration.
Though the NS7 is pictured, this section also applies to V7 calibration. If you are calibrating a V7,
disregard references to the "left" or "right" Decks and follow all steps on that specific V7's controls.
1.
If you have uploaded new firmware, the left Deck's HOT CUE BUTTON 1 will flash twice, indicating that you should recalibrate it.
2.
Disconnect the cable from the USB port and make sure the NS7 / V7 is off. While holding the right Deck's HOT CUE BUTTONS 1
and 3, turn the NS7's / V7's power on. HOT CUE BUTTONS 1-5 should flash twice.
3.
Wait 10-20 seconds.
4.
Set all faders and knobs to the maximum or right-most position. The PITCH FADERS should be at the bottom, which is their
maximum. (See image below.) The left Deck's HOT CUE BUTTON 1 will light up.
5.
Press the lit left Deck's HOT CUE BUTTON 1. It will flash twice.
All manuals and user guides at all-guides.com
33