AKSE Uninstall / install splash guard
050 Maintenance and inspection
Service group does not contain any maintenance and in-
spection points.
060 Error diagnosis
Measurements in case of excessive current consumption
of the brush motor.
Overload
Power consump-
stage
tion
1
35...40 A
2
45...50 A
3
> 65 A
Note
Bp variant:
After switching off the brush motor, the error message
"ERR B" is shown in the display.
070 Peculiarities/ others
The service group does not contain any peculiarities.
Switch-off time
30...40 s
1...10 s
0,2 s
1 Retainer disc brush
2 Motor shaft
3 Fitting key
Remove the retainer disc brush from the motor shaft.
Note
Use puller tool if necessary.
Installation information
Ensure the correct seating of the feather key during instal-
lation.
1 Splash guard
Pull off splash guard.
For detailed fault diagnosis see:
Faults
English 9.808-230.0 Rev. 01 (03/20)