Descargar Imprimir esta página

caprari K+ Serie Manual De Uso Y Mantenimiento página 20

Electrobombas sumergibles para líquidos cargados
Ocultar thumbs Ver también para K+ Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
K.M150N.. / K.M100N.. / K.W100N.. / K.D200N.. / K.M200P.. / K.D250P..
2.
EXAMPLE OF AN ELECTRIC PUMP DATA PLATE
CE
II 2G Ex db h IIB T4 Gb - Flame-proof classification (only for models K...-...X...) see paragraph 8
I M2 Ex db h I Mb
TÜV IT22 ATEX...X
GB
Production date
TYPE
Complete electric pump code
Serial N°
P1 [kW]
Mains power draw
P2 [kW]
Pump power draw
IP68
Motor protection level (according to IEC 529)
H [m]
Head range
S.F.A. [A]
Power draw according to service factor
∇ [m]
Maximum immersion depth
3.
EXAMPLE OF ...X... - MOTOR DATA PLATE (for flameproof models only)
MOTOR TYPE
Complete motor code
cos ϕ
Power factor
3 Ph ~
Three-phase a.c. power supply
S1
Continuous service with motor completely submerged
I.E.C. 60034-1
Standards used to establish the electrical characteristics
I. Cl.
Motor insulation category
S3
Intermittent service (in 10 minute cycles)
20
f [Hz]
Frequency
U [V]
Mains voltage / Type of connection
I [A]
Rated power draw
n [min-1]
Rotation speed
Q [l/s]
Flow rate range
S.F.
Service factor
t.max 40°C/105°F
Maximum temperature of pumped fluid
H max [m]
Maximum head
Caprari S.p.A.

Publicidad

loading

Este manual también es adecuado para:

K.m150nK.m100nK.w100nK.d200nK.m200pK.d250p