The cut-off machine is now ready for
use.
Switch off engine
N
Slide Master Control lever (3) to
STOP or 0
Additional hints on starting
If the engine does not start
The choke lever was not returned to o
in time after the engine turned over for
the first time.
N
Move Master Control lever to
START = starting throttle position
N
Set the choke lever to e = warm
start, even if the engine is cold
N
Pull the starter rope through
10-20 times to ventilate the
combustion chamber
N
Restart the engine
If the tank has been drained
completely
N
Refueling
N
Press the fuel pump bulb 7-10 times
– even if it is full of fuel
TS 700, TS 800
N
Set the choke lever in accordance
with the engine temperature
N
Restart the engine
Air Filter System
Basic information
The average filter life is more than 1
year. Do not dismantle the filter cover
or fit a new air filter unless there is a
noticeable loss of engine power.
In the long-life air filter system with the
cyclone pre-separation system, dirty air
is drawn in and deliberately rotated. The
larger and heavier particles carried in
the air are thus expelled and extracted.
Only pre-cleaned air enters the air filter
system and the result is extremely long
filter life.
Replacing the air filter
Only if there is a noticeable loss of
engine power
4
2
1
3
N
Remove the locking screw (1) on
the filter cover
N
Remove the filter cover (2)
N
Remove all coarse dirt from the area
around the filter and the inside of the
filter cover