Setting up a connection to the ECU
The tasks described in this section may only
be carried out by a qualified electrician.
If the product is connected to a terminal device (e.g.
PC, laptop), the product can be configured and
status information can be retrieved. Configuration
takes place via the web interface in a current web
browser. The web interface is password-protected.
As of firmware version 5.22, there are two different
web interfaces; one for "users" and the other one
for "operators". Entering the desired user when log-
ging in, opens the corresponding web interface.
The required password is included in the setup
data sheet.
User
Web interface
user
User web inter-
face for the EV
driver
1 "7.3 User web
interface"
[
 38]
}
operator
Web interface
for commission-
ing by a qualified
electrician
For commissioning, the web interface for qualified
electricians (operator) has to be used. This is here-
inafter referred to as "web interface".
The setup data sheet is divided into two
sections. The first section is intended solely
for qualified electricians and must therefore
be detached before handing it over to the
user.
The following options are available for setting up a
connection to the ECU:
6.6.1 Via USB
u Connect terminal device (e.g. PC, laptop) and
1 "6.3 Connections on the ECU" [} 23]
Possible settings
n Change char-
ging mode
n Export char-
u Open web browser.
ging statistics
n ...
u Enter the user name (operator) and password of
n Setting the
maximum
1 Password: See Commissioning data sheet
charging cur-
rent
6.6.2 Via Ethernet
n Connecting
an external
Only valid for the networkable product variants.
energy meter
u Connect terminal device (e.g. PC, laptop) and
n ...
u Configure the network of the terminal device as
u Open web browser.
u Enter the user name (operator) and password of
ECU with a USB cable.
If the driver is not automatically installed un-
der the Windows operating system:
u Navigate to "Control Panel" > "Device
Manager" > "Other devices".
u Right-click on "RNDIS/Ethernet Gadget" >
"Update Driver Software" > "Search for
driver software on the computer" > "Se-
lect from a list of device drivers on the
computer" > "Network Adapter" > "Mi-
crosoft Corporation" > "NDIS-compatible
remote device".
ð The driver is installed.
The web interface can be reached via http://
192.168.123.123.
the master charging point.
ECU with an Ethernet cable. To do this, use the
Ethernet port on the Ethernet surge protection.
follows:
n IPv4 address: 192.168.124.21
n Subnet mask: 255.255.255.0
n Standard gateway: 192.168.124.1
The web interface can be reached via http://
192.168.124.123.
the master charging point.