ADJUSTMENTS
NOTE: Carry out this operation on
both the gas solenoid valves.
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Open the hatch (A).
2)
Undo the screw (B) of the pressure measure-
3)
ment point (intake pressure) and the screw
(C) of the pressure measurement point (out-
put pressure).
Connect the pressure gauge (E) to the pres-
4)
sure measurement point.
Turn the gas supply tap back on.
5)
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Open the hatch (A).
2)
Undo the locking screw (B).
3)
Set the bush (C) at the distance as shown in
4)
the fi gure.
Tighten the screw (B). After making the set-
5)
ting, seal the screw with paint.
Close the hatch (A) when the operation is
6)
complete.
3269860_inst_GB_rev.2
ADJUSTING GAS SOLENOID VALVE
A
ADJUSTING BURNER PRIMARY AIR
Switch on the appliance and carry out a
6)
cooking cycle without food at the maximum
temperature.
Turn the screw (D) and check that the pres-
7)
sure gauge (E) reading complies with the val-
ues (see table at back of manual).
Switch off the appliance, turn off the gas sup-
8)
ply tap and disconnect the pressure gauge (E).
Retighten the screws (B-C).
9)
Close the hatch (A) when the operation is
10)
complete.
E
D
C
B
A
ENGLISH
50
48
46
44
40
38
36
B
C
29±1mm