ENC
FC
SB
RECEIVER CARD
BATTERY CHARGER
B71/BC
2x12
1,2 Ah.
V
or
2x12
4,5 Ah
V
Only AGM type
BATTERY CHARGER
B71/BC
WIFI
58
DESCRIPTION
Open control signal input (N.O.).
WARNING: persistent activation of the opening command prevents automatic reclosure; the automatic
reclosure time count is resumed when the opening command is released.
Close command input (N.O.).
Step by step mode command input (N.O.).
The function of the control is determined by parameter
Partial open control signal input (N.O.).
Set by default to 50% of completely open position.
Power feed for external devices. See technical characteristics.
Connecting B72/BRCL power unit for
(24 V
Connector for connecting to encoder installed on motor.
WARNING! Always disconnect from electrical power before disconnecting or connecting the encoder
cable.
In case of encoder replacement, repeat the acquisition procedure.
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
when the limit switch is activated.
WARNING: repeat the travel acquisition procedure after each adjustment to the limit switches.
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector (N.C.) for connecting release contact.
Turning the motor release pin stops the gate stops and no command signals are accepted.
WARNING! Once the release pin has been reset, if the gate is in an intermediate position, without activa-
ting a limit switch (if one is installed), the control unit starts a position recovery procedure (see chapter
20)
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector for plug-in radio receiver board.
The control unit has two radio remote control functions by default:
The programming buttons PR1 and PR2
In the event of a mains power loss, the controller unit is powered by the batteries. When battery power
is used,
is restored or until the battery voltage drops below the minimum permissible limit. In this case,
(Battery Low) is shown on the display and the controller unit accepts no commands.
WARNING! the batteries must always be connected to the electronic controller unit in order to charge.
Periodically (at least every 6 months), check that the battery is in good working order.
Two battery kits are available:
• Two 12 V
, 1.2 Ah batteries installed in the automation system itself.
• Two 12 V
, 4.5 Ah batteries installed in an external case.
For more information, refer to the installation manual for the B71/BC battery charger.
To install the charger and 12V 1.2 Ah batteries:
• Remove the cover.
• Pull out the tray located above the control unit.
• Disconnect the cables coming from the transformer from the POWER IN terminal of the control unit and
connect them to the charger terminal.
• Connect the red-black cables of the wiring, supplied with the battery, to the POWER IN terminal of the
control unit.
• Place the 12V 1.2 Ah batteries in the prepared compartment, paying attention to the polarities.
• Close the cover.
To reduce battery consumption, the positive power supply of the photocell transmitters can be connected
to the SC
closed, the control unit removes power from the devices.
This IP device allows, using any internet browser, the complete management of the control panel both in
proximity (point-to-point connection) and via cloud (remote connection).
.
- duty cycle 50%).
.
).
).
or
. In this way, when the gate is fully open or fully
, while
F). The gate stops