9.3
Acquisition procedure without limit switches
PROG
AP P-
x4 s
OPENING
OPEN
• Press and hold PROG for 4 seconds.
• Raise the release lever, the message
a calibration procedure. The operating parameters of the motor are determined during calibration.
• If the motor calibration procedure is successful, the message
• Return release pin. The acquisition procedure now starts.
•
is shown on the display (only if parameters
beam within 5 s, to prevent interrupting the procedure.
• When the mechanical opening stop is reached,
• The gate closes again until the mechanical closing stop is reached.
If the acquisition procedure is completed successfully, the display enters the command and safety device state display
mode. The gate retracts by the number of rotor revolutions selected in parameter
If the following error messages are shown on the display, repeat the acquisition procedure:
•
: calibration procedure failed.
•
: acquisition error. Press the TEST button to clear the error, and check the safety device in alarm state.
•
.
. : travel length error. Press the TEST button to clear the error, and check that gate is completely
closed.
ATTENTION: if the learning procedure was successful BUT the space left between the gate leaf and the
mechanical stop is not as desired, increase the value of parameter
maintains the same distance from the mechanical stop, adjust parameter
centimetres remain between the leaf stop and the mechanical stop.
For more information, see chapter 16 "Alarms and faults".
64
PH A5
PH A5
PH
A5
AU to
AU
to
CLOSING
is shown on the display.
appears on the display after a few seconds. The controller unit launches
,
,
FO
FO TO
(if FT are connected
or enabled)
CLOSE
,
are not disabled). Keep away from the photocell
.
.
. Check that when fully open, the sash
if necessary. Ensure that AT LEAST 3
x5 s
TO
AU to
Yes
.