Enabling of management for opening with automatic re-closure exclusion
If enabled, the exclusion of automatic re-closure only applies for the command selected via the parameter. For example:
if you set
, automatic re-closure is excluded following an AP command, but it is activated following a PP or PED
command.
NOTE: The command has open-stop-close or close-stop-open sequence activation function.
Disabled.
An AP (opening) command activates the opening manoeuvre. When the gate is fully open, automatic reclosure is exclu-
ded. A subsequent AP (open) command activates the closing operation.
A PP (step-by-step) command activates the opening manoeuvre. When the gate is fully open, automatic reclosure is
excluded. A subsequent PP (step-by-step) command activates the closing operation.
A PED (partial opening) command activates the partial opening operation. Automatic reclosure is excluded. A subse-
quent PED (partial opening) command activates the closing operation.
Tolerance on opening stop
NOTE: parameter are visible if limit switches are disabled on parameter
than or equal to that of par.
= minimum tolerance (rotor revolutions) ...
Tolerance on closing stop
NOTE: parameter are visible if limit switches are disabled on parameter
less than or equal to that of par.
= minimum tolerance (rotor revolutions) ...
Advance on stop on full opening
NOTE: parameter are visible if limit switches are disabled on parameter
To set an advance on stop of approx. 3cm set the following values for parameter
= minimum advance (rotor revolution) ...
Advance on stop on full closing
NOTE: parameter are visible if limit switches are disabled on parameter
To set an advance on stop of approx. 3cm set the following values for parameter
= minimum advance (rotor revolution) ...
Setting reverse time after activation of sensing edge or obstacle detection (crush prevention)
This sets the reverse manoeuvre time after activation of the sensing edge or the obstacle detection system. The gate co-
mes to a stop after reversal dues to activation of the sensing edge or obstacle detection system at the end of manoeuvre
deceleration speed. As a result, the effective reversal manoeuvre time is slightly longer than the set time.
From 0 to 60 s.
Setting motor torque
Increasing or decreasing the value of the parameter increases or decreases motor torque and, as a result, adjusts
obstacle detection sensitivity.
Use values below
ONLY for particularly lightweight installations not exposed to severe weather conditions (strong
winds or very cold temperatures).
= -35%;
= -25%;
= -16%;
= default motor torque setting.
= +8%;
= +16%;
= +25%;
Setting obstacle impact force sensitivity
If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact force exerted
on obstacles is too high, reduce the value of parameter
Low motor torque:
= minimum obstacle impact force ...
N.B.: only use these settings if the medium motor torque values are not suitable for the installation.
Medium motor torque. Recommended setting for adjusting force settings correctly.
= minimum obstacle impact force ...
70% of maximum motor torque, 1 s of reaction time. Sensing edge is compulsory.
80% of maximum motor torque, 2 s of reaction time. Sensing edge is compulsory.
= maximum tolerance (rotor revolutions)
= maximum tolerance (rotor revolutions)
= maximum advance (rotor revolutions)
= maximum advance (rotor revolutions)
= -8% (reduced motor torque = increased sensitivity).
= +35% (increased motor torque = reduced sensitivity).
.
= maximum obstacle impact force
= maximum obstacle impact force.
(
); adjust the value of par.
(
) ; adjust the value of par.
(
)
:
(
)
:
to be less
to be
69