9
Travel acquisition
For the system to function correctly, the gate travel must be acquired by the control.
9.1
Before starting:
1. Select the automation system model installed with the parameter
KEY:
HIGH SPEED Motor
SELECTION
MODEL
TW90/800
TW90/820
TW90/600/HS
TW90/620/HS
TW90/800/R
TW90/820/R
2. Select the position of the motor relative to the gate with the parameter
with the motor installed on the right hand side of the gate (seen from interior side).
OPENING ON THE LEFT
3. If limit switches enabled (
the mechanical stop
CLOSING LIMIT SWITCH
4. Check that the operator present function is not enabled (
OPEN
STOP
CLOSE
5. Move the gate into the closed position.
6. Press TEST (see TEST mode in chapter 9) and check the command signal and safety device states. If any safety
devices are not installed, jumper the relative contact or disable the device from the relative parameter ( ,
,
,
and
).
CLOSE
62
REVERSIBLE Motor
MOTOR TYPE
/
800kg IRREVERSIBLE
600kg HIGH SPEED
(see chapter 13 "Special Parameters for High Speed Motor")
800kg REVERSIBLE
(see chapter 14 "Special Parameters for Reversible Motor")
OPENING ON THE RIGHT
): adjust limit switches so that, after activation, the gate stops slightly in advance of
OPENING LIMIT SWITCH
15
15
TEST
da
da
ta
ta
with limit switches enabled
FC
FC
with limit switches disabled
00
00
.
CONFIGURATION
. The default setting for this parameter is
).
TEST
SEE CHAPTER 16 and 17
No
Until ...
TEST
PROG
AP P-
No
Press and hold on
Yes
TEST
ACQUISITION
PROCEDURE
CHAP. 10.2
Yes
TEST
ACQUISITION
PROCEDURE
CHAP. 10.3
,
,
ACQUISITION
PROCEDURE
CHAP. 10.2