art_01 cassette awning installation instructions
Wall bracket set (bracket set)
1.19. Bracket arrangement and pull-out forces for WALL installation
!
Make sure to follow important installation information!
All supplied brackets must be used and the brackets must also be installed using all fi xation points. The pull-out forces must be observed (see page 7).
Wall brackets
Wall bracket WB 20/21
Standard wall bracket
With left and right version
2 fi x. points per bracket
2 x ø12
Wall installation
20
4 x Ø 17
40
4 x Ø 38
Please note: With this type of awning, the brackets can only be installed on the very outside in the area of the functional bearings.
The centre-to-centre distance cannot be changed.
Fix. points = fi xation points; B-set = bracket set; WB = wall bracket; CB = ceiling bracket; RB = recess bracket
6
4 x Ø 17
Wall panel WB 24/25
With left and right version
4 x Ø 38
4 fi x. points per bracket
4 x Ø 17
4 x Ø 38
KI bracket set – standard wall
bracket set
Consisting of 1 piece WB 20 (left)
and 1 piece WB 21 (right). The
brackets are also the awning's side
bearings.
A total of 4 fi x. points
KM bracket set – wall bracket set
Consisting of 1 piece WB 24 (left)
and 1 piece WB 25 (right). For ins-
tallation on difficult substructures.
A total of 8 fi x. points
KL bracket set – wall bracket set
Consisting of 2 pieces WB 23
(each with 1 x steel plate) for ins-
tallation on critical substructures.
A total of 12 fi x. points
HW bracket set – recess bracket
set
Consisting of 1 piece RB 1 (left)
and 1 piece RB 2 (right), for aw-
ning installation via the standard
wall bracket WB 20/21.
A total of 4 fi x. points
Steel plate WB 23
For left and right
lichte Nischenbreite
6 fi x. points per bracket
Anlagenbreite
Anlagenbreite = lichte Nischenbreite -80 mm
lichte Nischenbreite
6 x Ø 17
20
Anlagenbreite
Anlagenbreite = lichte Nischenbreite -40 mm
40
20
20
40
40
Recess bracket RB 1/2
With left and right version
2 fi x. points per bracket
2 x Ø 15
20
40
20
20
40
40
Subject to technical changes, edition 09/2023