Pull-out forces and bracket sets for wind resistance class 1
!
In order that the wind speed specified by us or the wind resistance class specified by us is valid, the installer must match the fastener to the substructure present. You will
receive mounting brackets for installation on concrete (C 20/25) in the case of orders received which do not contain any information about the mounting substructure. Please note
that these brackets may not be suitable for installation on other substructures. The recommended type and quantity of brackets per product must be installed to fulfil DIN EN 13561.
The specified plug pull-out forces and the installation and assembly information from the fastener manufacturers must be observed here (incl. the edge distances). Precise pull-out
forces depending on the insulating plaster thickness and the designed bracket set, as well as for installation on other substructures on request.
CEILING installation on concrete C20/25
in cm
250
300
350
N
863
988
1.113
150
Set M
KW
KW
KW
1.294
N
1.476
1.657
200
KW
KW
KW
Set M
N
-
2.048
2.295
250
-
Set M
KW
KW
-
-
3.045
N
300
-
-
KW
Set M
N
-
-
-
350
-
-
Set M
-
N = pull-out force in Newtons (N) per fixing screw;
Bracket set = provided bracket set (see overview on page 8)