Figure 2-80: Analog Load Cell Board Millivolt Jumper Location and Settings
The 2 mV/3 mV jumper settings are described in Table 2-9.
Jumper
W1

POWERCELL Board Jumper

Two jumpers on the POWERCELL board are designed W1 and W2. If the
application contains more than 14 POWERCELLs, an external Power Supply (P/N
0917-0240) must be connected on pins 9 and 10 of the board connector, and
jumper W2 should be in the 24V position. Figure 2-81 shows the jumper's
locations and settings. Table 2-10 describes the purpose of each setting.
Jumper
W1
2-46
Table 2-9: Millivolt Jumper Description
On
Off
When the jumper is closed, the connected scale's load cell
X
setting is 2 mV/V.
When the jumper is open, the connected scale's load cell
X
setting is 3 mV/V
W2 (Pin 1)
W1
Figure 2-81: POWERCELL Card Jumper Locations and Settings
Table 2-10: POWERCELL Jumper Description
On
Off
This jumper should be closed when a network terminating
X
resistor is required to be installed in the terminal.
This jumper should be open when a network terminating
X
resistor is not to be installed in the terminal.
Description
Description