Function Of A Servomotor With Reversing Potentiometer - Grundfos 384-511 Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para 384-511:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
Servomotor
for pump type
DMX 226M
384-715
single pumps
DMX 226/2M
duplex pumps
384-716
with one
servomotors
DMX 226/2M
duplex pumps
384-717
with two
servomotors
DMX 226 groups
DMX 226 group M
DMX 24-8
DMX 37-5
DMX 52-8
DMX 60-3
DMX 82-5
DMX 100-8
DMX 130-3
DMX 142-8
DMX 160-5
DMX 224-5
DMX 255-3
DMX 380-3
-
-
-
-
-
8
Pump type
key,
Servomot
control
or kit
variant
AT8
95728747
AT9
95738846
ATP
95725880
AT3
95725666
AT5
95733971
AT4
95736504
AT8
95727848
AT9
95738847
ATP
95736505
AT3
95736506
AT5
95736507
AT4
95736508
AT8
95728749
AT9
95738837
ATP
95736510
AT3
95736511
AT5
95736512
AT4
95736513
DMX 226 group L
DMX 67-10
DMX 95-8
DMX 132-10
DMX 152-6
DMX 190-8
DMX 190-10
DMX 199-8
DMX 249-3
DMX 280-6
DMX 280-8
DMX 321-4
DMX 321-6
DMX 460-3.5
DMX 460-6
DMX 315-3
DMX 525-3
DMX 765-3
Spare
Power supply
servomotor
98721196
230 V, 50/60 Hz
98721198
115 V, 50/60 Hz
98721199
24 VAC, 50/60 Hz
98721200
230 V, 50/60 Hz
98721221
115 V, 50/60 Hz
98721222
24 VAC, 50/60 Hz
98721196
230 V, 50/60 Hz
98721198
115 V, 50/60 Hz
98721199
24 VAC, 50/60 Hz
98721200
230 V, 50/60 Hz
98721221
115 V, 50/60 Hz
98721222
24 VAC, 50/60 Hz
98721196
230 V, 50/60 Hz
98721198
115 V, 50/60 Hz
98721199
24 VAC, 50/60 Hz
98721200
230 V, 50/60 Hz
98721221
115 V, 50/60 Hz
98721222
24 VAC, 50/60 Hz
6.2.4 Function of a servomotor with reversing
potentiometer
The drive is positioned at the relevant terminals
(motor control open/closed) for the corresponding
direction of rotation by switching the supply voltage
on/off. The reversing potentiometer returns the
current position of the servomotor to the controller;
the position is held when the setpoint is reached.
6.2.5 Function of a servomotor with analogue
control and service switch
The microprocessor controller is integrated in the
drive housing. The controller positions the drive
based on a guide value (setpoint in mA signal) and
compares the specified setpoint with the actual drive
position (actual value). If the two values differ, the
drive is moved to the position determined by the
setpoint. The actual value is generated by a
potentiometer integrated in the drive.
Any positions can be assigned to 4 (0) mA and
20 mA at any time. The lower and upper current
limits
(4 (0) / 20 mA) are pre-programmed and cannot be
changed. The control direction can also be reversed
using a DIP switch " /inv".
In addition, this servomotor version is equipped with
an "Auto/Manual" service switch and a switch for
adjusting the positioning travel manually.
Control
variant
reversing
potentiometer
analogue
control
reversing
potentiometer
analogue
control
reversing
potentiometer
analogue
control

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

384-711384-714384-715384-716384-717

Tabla de contenido