Layout With Visible Laser (Laser Pointer); As-Built; As-Built With Prism - Hilti POS 150 Manual De Instrucciones

Ocultar thumbs Ver también para POS 150:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 142
8.1.1.1 Total station "loses" prism
Total station and prism maintain an optical connection. There must therefore be a continual line of sight between the
total station and prism. If objects interfere with or interrupt this optical connection, it is highly likely that the optical
connection between the prism and total station will be lost.
To reconnect the prism with the total station, use the search button on the controller. This opens a dialog with functions
to search for the prism.
Before initiating the search, make sure that the search parameters in the menu "Settings" are set in accordance with
the requirements.

8.1.2 Layout with visible laser (laser pointer)

In this procedure, the EDM is set to "Laser ON". This ensures that for practical setting out with the "red dot", the
layout point is directly selected and the layout position virtually marked with the red dot.
As the red laser is more easily seen in lower ambient light, this application is primarily used indoors.
To enable the layout point to be directly selected in three dimensions, the station must be set up with the height values
specified.
It is, however, also possible to set out using floors or ceilings without specification of heights. The laser must first be
trained onto the area. In this case, the software attempts to find the corresponding point position or the corresponding
plumbline on the area in question.
NOTE
The application "Layout" with the "red" laser is suitable for layouts on floors and ceilings. The application is not suitable
for layouts on the wall.

8.2 As-built

8.2.1 As-built with prism

To measure points as built, the position is first defined with an entry.
Select point with coordinates. The total station
rotates to the selected point and connects with
@
the prism.
Enter angle directions. The total station rotates
;
to the selected point and connects with the
prism.
Select or change the current prism. Automatic-
=
ally sets the corresponding prism constant.
Confirm dialog
%
Start/stop prism search
&
Switch over guide light. Off – Normal – Fast –
(
Auto
Switch over EDM. Auto – Manual – Laser (off) –
)
Laser (on)
en
53

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pos 180

Tabla de contenido