Table of Contents
Safety ....................................................................................2
Description................................................................................2
Appropriate Use..................................................................4
Pump Performance and Specifications..............................4
Installing the Pump.....................................................................4
Setting the Pump Speed............................................................6
Maintenance and Repair............................................................7
Pump Dimensions.....................................................................9
Repair Parts List.......................................................................11
Trouble Shooting.....................................................................12
French Translation.................................................................14
German Translation.................................................................26
Spanish Translation..................................................................38
Read and carefully observe these operating instructions before
unpacking and operating the pump! The pump must be oper-
ated, maintained and repaired exclusively by persons famil-
iar with the operating instructions. Local safety regulations
regarding installation, operation and
maintenance must be followed.
Operate this pump only after safety instructions and this ser-
vice manual are fully understood.
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.

Safety Instructions

This equipment generates very high grease pressure.
Extreme caution should be used when operating this equip-
ment as material leaks from loose or ruptured
components can inject fluid through the skin and into the
body causing serious bodily injury. Adequate protection is
recommended to prevent splashing of material onto the skin
or into the eyes.
If any fluid appears to penetrate the skin, get emergency
medical care immediately. Do not treat as a simple cut.
Tell attending physical exactly what fluid was injected.
Inspection
If overpressurizing of the equipment is believed to have oc-
curred, contact the factory authorized warranty and service
center nearest you for inspection of the pump.
© Indicates change
Page Number - 2

Safety

Specialized equipment and knowledge is required for repair of
this pump. Contact the factory authorized warranty and service
Page
center nearest you for repair or adjustments other than mainte-
nance specified in this manual.
Annual inspection by the factory authorized warranty and ser-
vice center nearest you is recommended.
A list of factory authorized warranty and service centers is
available upon request.
Damaged Pumps
Any pump that appears to be damaged in any way, is badly
worn or operates abnormally, shall be removed from use until
repairs are made. Contact the factory authorized warranty and
service center nearest to you for repairs.
85552 - Pump for 5 gallon pail, speed range 5 - 50 RPM
maximum pressure rating 5,000 psi
85553 - Pump for 120 lb. drum, speed range 5-50 RPM
pressure rating 5,000 psi
85554 - Pump for 60 lb. drum, speed range 9-93 RPM,
maximum 5,000 psi
85566 - Pump for 120 lb. drum used on wayside rail
lubricators, speed range 9 - 93 rpm,
maximum 5,000 psi.
85567 - Pump for 60 pound drum, speed range
36 - 360 RPM, maximum pressure rating 5,000 psi
85568 - Pump for 90 and 120 lbs. drum, speed range
36 - 360 RPM, maximum pressure rating 5,000psi
85569 - Pump for 5 gallon pail, speed range 9.5 - 100 RPM,
maximum pressure rating 2,500 psi.
85587 - Pump for 5 gallon pail, used on wayside rail
lubricators, speed range 9-93 rpm.
85591 - Pump for 400 lb. drum, speed range 36-360 RPM,
maximum pressure rating 5,000 PSI.
©
274873 - Pump for 5 gallon pail, 7:1 ratio, 1600 psi,
25-260 RPM, used on hose reel pump assemblies.
275626 - Pump for 60 lb. drum, 7:1 ratio.
©
General Description
The Lincoln Industrial rotary DC electric pump uses a 24VDC
motor and either a single a two stage planetary gear drive.
Grease output is proportional to the pump RPM. The pump is
primarily designed for centralized lubrication systems such as
the Single Line Parallel, Single Line Progressive and Two Line
systems.
The pump is driven by the rotary motion of the electric motor.
Rotary motion is converted to reciprocating motion through an
eccentric crank mechanism. The reciprocating action causes
the pump cylinder to move up and down. The unit is a posi-
tive displacement double acting pump as grease output occurs
during both the up and down stroke. The pump motor employs
an integral speed control capable of reducing pump speed to
10% of its maximum value.
During the down stroke, the pump cylinder is extended into
the grease. Through the combination of shovel action and
vacuum generated in the pump cylinder chamber, the grease