WEG ODP Instrucciones Para La Instalacion Y Mantenimiento página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
L1
L2
L3
3x
THERMISTORS LEADS
4.11 - Start-Up
i
f The moTor is running bare
,
shafT
The key musT be fasTened
or removed before sTarTing
a) The motor must start and operate smoothly.
In case this does not occur, turn it off and
check all connections and the mounting
before starting it again.
b) In case there is excessive vibration, check
if the fixing screws are correctly fastened.
Check also if the vibration comes from a
neighbor machine. Periodical vibration check
must be done.
c) Run the motor under rated load for a short
period of time and compare if the running
current is in accordance to the nameplate
current.
5 - MAINTENANCE
Any service in electric machines should only
be carried out when it is completely stopped
and all phases disconnected from the power
supply.
safeTy check lisT
General Inspection
 Check motor periodically.
 Keep motor clean and ensure free air flow.
 Check seals and replace them, if required.
 Check connections as well as supporting
screws.
Overtemperature
Protected motor
with thermistors
RELEASE DEVICE
.
warning:
 Check bearing condition and pay attention
to: Any excessive noise, vibration, bearing
temperature and grease condition.
 When a change, under normal conditions
is detected, check the motor and replace
required parts.
do noT reuse damaged or worn
parTs
supplied by The facTory
Periodical inspection depends on motor type
and on application conditions.
5.1 – Lubrication.
follow regreasing inTervals
is fundamenTal for proper moTor
operaTion
5.1.1 - Machines without Grease Nipples
Motors up to frame size 200 are normally
fitted without grease fittings. In these
cases the regreasing shall be done during
preventive
maintenance
attention to the following aspects:
 Take motor apart carefully.
 Take all the grease out.
 Wash the bearing with kerosene or diesel.
 Dry the bearings.
 Regrease the bearing immediately.
5.1.2 – Motors Fitted with Grease Fitting
It is strongly recommended to grease the
machine while running. This allows the
grease renewal in the bearing housing.
When this is not possible due to rotating
parts by the grease device (pulleys, bushing,
etc) that offer some risk to physical integrity
of the operator, proceed as follows:
 Turn off the motor
 Clean the area near the grease nipple.
 Put approximately half of the total grease
and run the motor for 1 minute at full speed.
Then turn off the motor and pump in the rest
of the grease.
 The injection of all the grease with the
motor in standstill can make the grease
penetrate into the motor, through the bearing
housing inner seal.
Inspections intervals depend on motor type
and on application conditions.
use only manual grease gun for
lubricaTion
10
.
replace Them by new ones
.
.
service
.
.