Operating Conditions - WEG ODP Instrucciones Para La Instalacion Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
and/or water inside the terminal box, cable
glands or threaded pipe in the lead passage
holes must be installed. It must be equal or
higher IP rating than the motor.
l
ead connecTion insulaTion
inside The Terminal box musT be
done wiTh an insulaTing maTerial
compaTible wiTh moTor Thermal
class which is shown on The
moTor nameplaTe
If installation and safety instructions are not
followed accordingly, warranty may be void.

4.2 - Operating Conditions

In general electric motors are designed for
operation up to an altitude of 1000m above
sea level for an ambient temperature ranging
from -20ºC to 40ºC. Any variation is stated
on the nameplate.
The recommended installation distance be-
tween air inlet from the motor and the wall
should be at least ¼ of the air inlet diameter.
A person should have enough room to carry
out cleaning services.
Machines that are cooled with ambient air,
air inlet screens must be cleaned at regular
intervals so as to ensure free air circulation.
Warm air can not return to the motor.
- For vertically mounted motors with air inlet
on top, the air opening must be protected by
a proper cover so as to avoid dropping of
foreign materials on the motors.
- Considering that direct sun heat causes
increase in temperature, externally installed
motors should be always protected against
weathering.
c
ompare The currenT
frequency
oTher values required by The
applicaTion wiTh moTor nameplaTe
informaTion
ODP MOTORS – Open motors (IP21, IP23)
are machines designed for operation in clean,
dry areas, with enough air circulation for
proper cooling. These motors should never
be used in areas with flammable materials.
Open motors may cause sparks and release
cast particles under any eventual insulation
failure (short-circuit).
TEFC MOTORS – Totally enclosed motors
are machines suitable to operate in areas
.
,
,
volTage
,
,
speed
ouTpuT and
.
with moisture, dirt and/or corrosive materials
either in enclosed or open environments.
4.3 - Foundation
Motors provided with feet must be installed
on solid foundations to avoid excessive
vibrations.
All motors must be fully fixed and aligned.
The purchaser is fully responsible for the
foundation.
Metal parts must be painted to avoid
corrosion.
The
foundation
sufficiently strong to support any shock. It
must be designed in such a way to stop any
vibration originated from resonance.
Note: Considering that rotation direction is
important for correct operation, then check
it carefully before connecting motor to the
load.
4.4 - Drain Holes
Make sure drains are placed at the lower motor
position when the mounting configuration
differs from that specified on the motor
purchase order.
4.5 – Balance
w
hen special balance is
required
All motors are dynamically balanced at the
factory with half key.
Transmission elements such as pulleys, cou-
plings etc must be dynamically balanced with
half key before installation.
Use always appropriate tools for installation
and removal.
4.6 – Alignment
a
lign The shafT ends and use
flexible coupling
possible
Make sure that the motor mounting devices
do not allow modifications on the alignment
and further damages to the bearings.
When assembling a coupling, make sure to
use suitable equipment and tools to protect
7
must
be
uniform
,
.
conTacT The facTory
,
whenever
.
and

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tefc

Tabla de contenido