Mma System Start-Up; Adjustment System For Mma & Mma Cel Welding Mode; Parameters Setting Mode. Mma & Mma Cel Processes; Adjustment System For Mma & Mma Cel Setting Parameters - GALAGAR INVERMIG SYNER 230 MP Bi-PULSE Manual Técnico De Instrucciones

Equipos inverter multiproceso. control sinérgico soldadura mig/mag
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.6.2. MMA SYSTEM START-UP.

1º) Make sure the mains voltage is 230 V.
2º) Connect electrode-holder clamp 11 to polarity recommended by the electrode manufacturer. Normally to
positive pole.
3ª) Connect earth clamp 9 to welding table or piece to be welded. Check correct connection of welding masses.
4º) Check that the electrodes are not damp. If necessary, preheat electrodes for at least one hour with oven 16.
5º) Connect supply cable 1 with the suitable plug to the relevant single-phase tap.
See section 2.2.
3.6.3. ADJUSTMENT SYSTEM FOR MMA / MMA CEL WELDING MODE.
3.6.4. PARAMETERS SETTING MODE. MMA / MMA CEL PROCESSES.
PROCESS
MMA
MMA CEL
3.6.4.1. ADJUSTMENT SYSTEM FOR MMA / MMA CEL SETTING PARAMETERS.
P1: SELECT PROCESS
CEL

3.6.4.2. SETTING PARAMETERS RESET. FACTORY PARAMETERS BY PROCESS.

GALA INVERMIG SYNER 230 MP Bi-PULSE
P1: SELECT PROCESS
Setting parameters
HOT; ARF
HOT; ARF
CEL
P1: ENTER/EXIT TO
PARAMETERS SETTING
MODE
SETTING PARAMETERS
PARAMETER RESET OF SELECTED PROCESS
1 s
E2: ADJUST WELDING
CURRENT I
D1:
CEL
E1: SELECT CYCLE
E2: ADJUST VALUE
PARAMETER
D2 :
P1+P2:
1 s
D1:
(A)
2
A
P1: SAVE
PARAMETERS
D3 :
SAVED PARAMETERS
65

Publicidad

Tabla de contenido
loading