Tabla de contenido

Publicidad

3-10
Installing the Drive
Rated
Rated
Current
Inductivity
(Aeff)
(mH)
6
4.88

Line Choke

Cables are considered to be electrically sensitive, clean or noisy. A line choke is used to reduce
harmonic emission to meet the limits of EN61000-3-2.
signal/control cable
(sensitive)
power
supply
cable
(clean)
fuse or suitable
circuit breaker
(RCD not
recommended)
The choke is for use on the following drive:
Phase Drive Nominal
Input Voltage
(V)
3
400
A
B
C
(mm)
650 Frame 2, 3-phase, 400V, 0.37kW/0.5Hp
148
76
151
* dimension is dependent of the air gap
(noisy)
drive
line
choke
Drive Power
Rated
(kW/hp)
Current
(Aeff)
0.37/0.5
6
D1
D2
D3
E1
90
100
136
39
motor
cable
motor
(noisy)
Rated
Choke
Inductivity
Part Number
(mH)
4.88
CO467763U003
(Europe)
E2
E3
F*
G Fixing
45
49
110 69
650 Series AC Drive
Weight
Screws
(kg/lbs)
M4
2.1/

Publicidad

Tabla de contenido
loading

Tabla de contenido