Analog Inputs/Outputs; Digital Inputs; Digital Outputs; Cabling Requirements For Emc Compliance - Parker 650 Serie Manual De Producto

Tabla de contenido

Publicidad

Analog Inputs/Outputs

Range
Impedance
Resolution
Dynamic Response

Digital Inputs

Operating Range
Input Current
Sample Interval

Digital Outputs

Nominal Open Circuit Output Voltage
Nominal Output Impedance
Rated Output Current

Cabling Requirements for EMC Compliance

Cable Type
(for EMC Compliance)
Segregation
Length Limitations
With Internal AC Supply
EMC Filter
Length Limitations
Without Internal AC
Supply EMC Filter
Screen to Earth
Connection
Output Choke
* Maximum motor cable length under any circumstances
Terminals AIN1, AIN2, AOUT1.
Inputs
0-10V and 0-5V (no sign) set via parameter
0-10V, 0-5V, 0-20mA or 4-20mA (no sign) set via
S
parameter
IP23 (AIN2)
Absolute maximum input current 25mA in current mode
Absolute maximum input voltage 24V dc in voltage mode
Voltage input 20k
Current Input <6V @ 20mA
10 bits (1 in 1024)
Sampled every 10ms
Terminals DIN1, DIN2, DIN3, DIN4.
0-5V dc = OFF, 15-24V dc = ON
(absolute maximum input voltage ±30V dc)
IEC1131
7.5mA @ 24V
10ms
Terminals DOUT2 (DOUT1 is reserved for future models).
23V (minimum 19V)
33
50mA
Power Supply Cable
Motor Cable
Unscreened
Screened/armoured
From all other wiring
From all other wiring (noisy)
(clean)
Unlimited
*25 metres
Unlimited
25 metres
Both ends
300 metres
maximum
Technical Specifications
Output
S
IP13 (AIN1)
0-10V (no sign)
Maximum rated output
current 10mA, with short
circuit protection
10 bits (1 in 1024)
Bandwidth 15Hz
24V
15V
5V
0V
Brake Resistor Cable
Signal/Control Cable
Screened/armoured
Screened
From all other wiring
(sensitive)
25 metres
25 metres
25 metres
25 metres
Both ends
Drive end only
9-6
ON
undefined state
OFF
650 Series AC Drive

Publicidad

Tabla de contenido
loading

Tabla de contenido