6 Putting into operation
6.4.2
Removing the cable assembly from the iCAT-WK adapter
1
2
Cable support
1
Cable binder
2
Control lead
3
Mounting the ROBO WH cable assembly
Fig. 10
6.5 Mounting the liner
EN - 16
3
4
Pneumatic line
4
Cable assembly line
5
Cable assembly line
6
1 Introduce control lead (3) into bore on the adapter.
2 Remove pneumatic line (4) to the clamping cylinder (9).
3 Cut off cable binder (2) at the cable support (1).
4 Remove the cable support (1).
5 Remove all lines of the cable assembly (5), (6), (7), (8) from the adapter
or unscrew them.
Mounting takes place in reverse order.
NOTE
• New still unused wire guide liners have to be shortened to the actual
length of the cable assembly.
• For handling the wire guide, please observe the enclosed wire guide
mounting instructions.
• Strip 350 mm of the insulation sheathing of the liner, after determining
the correct length.
9
8
7
Cable assembly line
7
Cable assembly line
8
Clamping cylinder
9
iCAT WH
3
4
5
6