iCAT WH
9.1 Cleaning the adapter, WK and iCAT WH
Clamping cylinder
1
Cleaning the
Fig. 12
1
adapter, WK and iCAT WH
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power source.
• Close off the compressed air supply.
• Switch off the entire welding system.
• Pull the mains plug.
1 Dismount the cable assembly
 see 6.4 Replacing the cable assembly on page EN-14
2 Clean the iCAT ROBO WH with compressed air.
3 Blow compressed air through the adapter.
4 Unscrew clamping cylinder (1) from the iCAT
5 Blow compressed air through the clamping cylinder bore
6 Blow compressed air through the wire conduit bore
7 Mount clamping cylinder and cable assembly again
9 Maintenance and cleaning