Setting motor torque

Increasing or decreasing the value of the parameter increases or decreases motor torque and, as a
result, adjusts obstacle detection sensitivity.
Setting obstacle detection sensitivity
If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact
force exerted on obstacles is too high, reduce the value of parameter 30.
Low motor torque:
N.B.: only use these settings if the medium motor torque values are not suitable for the installation.
Medium motor torque. Recommended setting for adjusting force settings correctly.
Maximum motor torque. May only be used if the door is equipped with a sensing edge.
Setting opening start acceleration
Setting closure start acceleration
sively at start of manoeuvre.
Setting opening speed (%)
Setting closure speed (%)
Setting number of automatic closure attempts after activation of sensing edge
or obstacle detection (crush protection)
From 1 to 3 automatic closure attempts.
.
Automatic closure is only performed if the door is completely open.
Setting photocell mode during door opening (FT1)
STOP. The door stops and remains stationary until the next command is received.
when the photocell is cleared.
is cleared.
Setting photocell mode during door closing (FT1)
STOP. The door stops and remains stationary until the next command is received.
when the photocell is cleared.