Alarms and faults

PROBLEM
The door does not open
or close.
Acquisition procedure
does not complete
correctly.
Remote control has lim
ited range and does not
work while automated
door is moving.
Remote control has lim
ited range and does not
work while automated
door is moving.
working.
Door open indicator
lamp does not work.
Door does not perform
desired manoeuvre.
N.B.
The next time a command is received, the alarm reappears on the display if the problem has not been resolved.
ALARM
POSSIBLE CAUSE
POWER
POWER
Fuse F1, F2 or F3 blown.
Input mains power voltage
fault.
Control initialisation failed.
Overcurrent detected in in
verter.
Travel data acquisition
error.
Motor not connected.
Both limit switches acti
vated.
error.
dentally.
Safety devices in alarm
state.
Travel length error.
Limit switch error.
The radio transmission is
impeded by metal struc
tures and reinforced con
crete walls.
Flat batteries.
light wires disconnected.
Bulb blown or wires discon
nected.
Motor leads crossed.
ACTION
Check power cable.
Replace fuse.
Always disconnect from mains power
before removing fuses.
Disconnect from mains power, wait
10 seconds then reconnect to the mains
and switch on.
unit if the problem persists.
Press the TEST button twice or perform
3 command requests in succession.
Check that open and closed limit
switches are positioned correctly.
ces are in alarm state.
Repeat acquisition procedure.
Check the motor cable.
Check connections of limit switches or
check for foreign objects in limit switch
blocks.
save.
Repeat acquisition procedure.
Check connections of safety devices.
Repeat acquisition procedure.
Check mains voltage
Move the door into the fully closed posi
tion and repeat the procedure.
Check that door closed limit switch is in
correct position.
Install the antenna outside.
Replace the transmitter batteries.
wires.