01/2006
2.5.6 DH.INI
Ejemplo:
[ACCESSMASKS]
\wks.dir\*.wpd\*.mpf =
\mpf.dir\*.mpf =
\cus.dir\*.spf =
2.5.7 DPDH.INI
[ACCESSLEVEL]
PROGRAMADOR=4
OPERADOR=5
ENABLE_DIALPROG=0
SetStandardWpSave=2
ENABLE_SIMULATION=7
2.5.8 DPSIM.INI
[ACCESSLEVEL]
SETUP=1
USER=3
OPERADOR=5
[MAIN]
EXTERN_MODAL=0
EXTERN_SIZE=150000
EXTERN_CHECK=1
SIM_LOAD_TOOLS=1
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D sl/840Di sl/840D/810D Puesta en servicio HMI (IAM) – Edición 01/2006
75775
75775
33773
;minimum level for changing setup standard:
;<>0: simulate program extern modal (see also
; EXTERN_SIZE,EXTERN_CHECK)
; simulate program extern modal, if program
; size >= EXTERN_SIZE
; only if EXTERN_MODAL<>0
; only if EXTERN_MODAL<>0
; <>0: reset tool data, if new workpiece is selected
; =0:
use current tool data, if new workpiece is selected
Puesta en servicio HMI-Advanced (IM4)
2 Ajustar funciones y parámetros