Descargar Imprimir esta página

Hoshizaki DBF-AS65WE-EU-HC Manual De Instrucciones página 20

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 133
U08 Self mode setting
U09 Mug tilting operation
U10 Reset number of mugs
U90 Reset settings
II. OPERATING INSTRUCTIONS
1. CLEANING BEER CIRCUIT
Although the beer circuit is cleaned before shipping, clean it again before use. See "III. 2. BEER CIRCUIT (DAILY)".
Check that the parts are installed in their correct positions. See "I. 1. CONSTRUCTION".
2. FILLING WATER TANK
Use only the specified water to fill the water tank. Use of any other water or mixture of salt, vinegar or juice may cause insufficient
ice storage, corrosion or perforation.
[a] HOW TO MAKE COOLING WATER
Electric conductivity (E.C.) of cooling water for water tank
Do not use tap water.
Fill the water tank with water having 100-300 μS/cm of E.C.
Measure the electric conductivity with conductivity meter.
* E.C.: Physical property to show the ability of conducting electricity.
Unit: μS(microsiemens)/cm
Below 100 μS/cm:
Compressor may not work resulting in poor cooling performance.
Above 300 μS/cm:
Excessive ice may build up on evaporator and freeze beer inside beer coil preventing beer from
being dispensed properly.
How to make cooling water with 100-300 μS/cm of E.C.
The capacity of the water tank of this unit is approx. 30 L.
Make the cooling water by dissolving 5 g of pure baking soda in approx. 10 L of distilled water,
and then add approx. 20 L of distilled water to fill the water tank.
Step 1
Measure 5 g of pure baking soda with nozzle cap (accessory).
Step 2
Fill a bucket with approx. 10 L of distilled water and stir well after adding the 5 g of baking
soda measured in step 1.
Rinse the nozzle cap after use.
0: No
1: Yes (no button operation is available except dispense/stop button)
* The self mode is reset when the manual dispensing mode is selected (by
lifting up the operation panel unit). To resume the self mode, switch to the
automatic dispensing mode (by pulling down the operation panel unit) and
press the dispense button.
0: Yes (mug is tilted while beer is being dispensed)
1: No (mug is kept upright while beer is being dispensed)
0: Manual
1: Manual or when sold out sensor detects
* To reset manually, press and hold the stop button for 3 seconds.
Initialize only the user settings
* To initialize, with "1" shown on the display, press and hold the stop button
for 3 seconds.
* If the settings are updated, "U90" appears on the display. If not updated, "0"
appears again.
NOTICE
IMPORTANT
Carefully read this before filling the water tank.
13
ENGLISH
0
0 - 1
0
0 - 1
0
0 - 1
0
0 - 1
Nozzle Cap
Nozzle Cap 5/6
(5 g)
Distilled Water
(approx. 10 L)
Bucket

Publicidad

loading