Descargar Imprimir esta página

SATA air vision 5000 Instrucciones De Servicio página 15

Ocultar thumbs Ver también para air vision 5000:

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions for SATA Breathing Protection Equipment
points on the air humidifier should
not leak. (For instance, feel, listen or
spray with water to detect leaks.)
Information!
If necessary, retighten screws
[28-3] (torque: 1.1 - 1.47 lbf ft
(150 - 200 Ncm)).
■ Do not use defective air humidifiers -
replace immediately.
■ Have defective air humidifiers re-
paired by SATA.
■ Manipulation of the pressure relief
valve is prohibited.
■ Do not modify the air humidifier.
■ Maintain the appropriate moisture
level in the breathing air to prevent
freezing the device.
2.7. Safety precautions for
air warmer/cooler
■ Only operate the air warmer within
a line temperature range of
+95°F
.
■ Only operate the air cooler within
a line temperature range of
+140°F
.
■ Before each use, always check the
air warmer/cooler for proper function
and any leakage with the breathing
protection hood connected.
■ Replace defective air warmers/cool-
ers.
■ Have defective air warmers/coolers
repaired by SATA.
■ Do not modify air warmers/coolers.
2.8. Safety precautions for
belt unit
■ Do not use belt unit for securing.
■ Avoid constrictions on body.
■ Do not use as carrying aid.
■ Use only in combination with suitable
SATA module parts.
3.
■ Safety quick-release couplings.
4.
Intended Use
The breathing protection equipment
is a part of the personal protec-
tive equipment (PPE) to protect
the wearer from inhaling noxious
substances from the ambient atmo-
sphere or from oxygen deficiency.
Use other than intended
The breathing protection equipment
is not intended for use in ambient
atmospheres with high levels of
radiation, heat or dust.
5.
+41 -
Technical data are listed in the
Chapter S-Special or Critical
User's instructions (see Chapter
+68 -
1.4).
6.
6.1. Breathing protection
■ SATA air vision 5000 breathing pro-
tection hood with installed breathing
air hose, connection nipple and visor
foil
■ Comfort head band, 2 pcs. (1 x
installed, 1 x loose)
■ CCS disks, 2 bags (red, black, green,
blue); red is installed
Safety Gear
Intended Use
Technical Data
Information!
Breathing Protection
Equipment Scope of
Delivery
hood scope of delivery
US
15

Publicidad

loading