Chapter 6
Preparation for Lithium-Ion Battery
Shipment
You can prepare stand-alone IMPRES 2, IMPRES, or other authentic Motorola Solutions Lithium-Ion batteries
for shipment by air cargo using an IMPRES 2 Multi-Unit Charger. Other battery types are faulted. If the
IMPRES 2 Lithium-Ion battery is equipped with a Sleep mode, the charger puts the battery to sleep upon
completion of Ship Lithium charge.
Prepare only stand-alone Motorola Solutions Lithium-Ion batteries for shipment. Remove the battery from the
radio before placing it into the charger.
DO NOT store a stand-alone battery in the charger. When preparation for Lithium Shipment is complete,
immediately remove the stand-alone battery from the charger.
Selection of Lithium Shipment supersedes calibration or reconditioning.
6.1
IMPRES 2 or IMPRES Battery
Table 17: Status Indications of a Lithium-Ion Battery Prepared for Shipment (IMPRES 2 or IMPRES
Battery is due for Calibration)
Status
Charger Powers On
Battery Detected
Battery Discharging
Rapid Charging
Ship Lithium Complete
Fault
●
Battery is not making
proper electrical contact
with the charger.
Charger Display
IMPRES 2
CHARGER
IMPRES 2
BATTERY
OR
IMPRES
BATTERY
SHIP LI DISCHRGE
xxx% Rated Cap
SHIP LI CHARGE
xxx% Rated Cap
LI READY TO SHIP
xxx% Rated Cap
WARNING:
NOT CHARGEABLE
REMOVE & REINSERT
OR
WRONG BATT TYPE
Chapter 6: Preparation for Lithium-Ion Battery Shipment
LED Indicator
Green for approximately 1 sec-
ond
Battery requires calibration: Al-
ternating amber and green for
four seconds.
Steady amber
Steady red
Alternating amber and green.
Flashing red
MN002407A01-AK