Descargar Imprimir esta página

Angelo Po 12WFAAA Manual De Uso E Instalación página 42

Cocina fuegos abiertos + armario caliente

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
230V/1N.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
IT
GB
DE
FR
ES
Important
Before it is put into service, the system
must be tested to check the operating con-
ditions of every single component and
identify any malfunctions. In this stage, it is
important to check that all health and safety
requirements have been complied with in
full.
To test the system, make the following checks.
1 - Check that the mains voltage is the same as
that of the appliance.
English
ELECTRICAL CONNECTION
A
TESTING OF THE APPLIANCE
2 - Pull off the knob (B).
3 - Undo the screws (C) and remove the control
panel (D).
4 - Connect the circuit-breaker (A) to the terminal
board (L) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual. Use a cable with at
least H05RN-F characteristics.
Important
When connecting, take care to connect the
neutral and earth lines.
5 - Replace the control panel (D) and the knobs (B)
on completion of the operation.
C
L
B
C
D
2 - Operate the appliance's circuit-breaker to
check the electrical connection.
3 - Turn on the gas supply tap and check that the
connections are right.
4 - Check that the mains gas is the same as that
used for commissioning of the appliance, and
carry out the conversion procedure if necessary
(see page 17).
5 - Check that the hob burners are igniting correct-
ly and their combustion.
6 - Check the gas pressure and flow-rate at mini-
mum and maximum settings and adjust if nec-
essary (see page 12).
- 18 -