Baker GA 950 / GA 550
Changing of further Settings Before Program Start
To adjust a preconfigured program, touch the button on the
keyboard with the "Master" symbol. The selected symbol is
displayed with a blue edge, and the "Settings" button (symbol
with sliding button) is shown in blue, which means it has been
activated.
Touching the "Settings" button (symbol with sliding button)
displays the settings menu with five program phases:
Freezing, Storage, Thawing, Proving, and Holding.
The opening menu shows that contain the duration,
temperature, and relative humidity values for the respective
program phase. By touching the
individual program phase, (for example) you select it to have its
values set. The fields are then opened (for example
for example, time, "Duration".
In order to deactivate a program phase, the symbol must be
selected, after which you press on it until the field "GREY" has
been saved. To reactivate the program phase, you must press on
it again until the symbol has its original color. If goods are placed
in the unit that has been refrigerated in advance, and the
program is started with storage, then under "BUTTON 1" you
must choose a selection; see the first section. For example, to
disconnect holding, you must make the same selection under
"BUTTON 5". With "OK" the values are accepted, and the menu
is closed. The selection menu "Save recipe" is then shown.
Saves the entered values temporarily and
accordingly runs the execution of the program
activated only once.
Enables storage of the changes in a special user-
defined program.
The menu will be exited without changes, i.e.
the changes will berejected.
buttons for the
) . The data entry menu is shown,
EN
16