Baker GA 950 / GA 550
HUMIDIFIER
Make sure the cabinet is standing on level ground and is upright. If necessary, the adjustable feet of the
cabinet can be used to achieve this. All feet should be in contact with the ground. This is necessary for the
proper operation of the cabinet door.
Do not place the cabinet next to any heat-generating devices such as ovens, grills, and deep fryers. Do
not expose to direct sunlight. The heat that may be radiated by walls or floors must be insulated with
appropriate insulating material. The cabinet should be placed as far as possible from any heat source.
If the cabinet is re-located, allow three hours before re-starting. Plastic protection or tape should be
removed from the outer surfaces.
Ensure the cabinet is positioned so sufficient fresh air can flow to/from the cooling circuit and around the
surfaces of the cabinet. Leave at least 500 mm free space from the top of the cabinet.
If two refrigerators or freezers are to be placed side by side, there should be at least 50 mm space between
them.
Do not block any vent holes.
PRELIMINARY CHECKS
Please note the following:
➢ The electrical conductivity of the water must be in the range: 200-800 μS/cm. (If the electrical
conductivity of the water is outside the above-mentioned standard range some controller settings,
might need adjustment to maintain proper steam production. These adjustments must be done by a
service technician and are described in the service manual.)
➢ The temperature of the inlet water must not exceed 40°C.
➢ The water pressure must be in the range 1-10 bar.
➢ A shut-off valve, a check valve, and a filter, if necessary, must be fitted to the supply pipe.
The cabinet is equipped with a humidifier that provides steam during
proving. The humidifier consists of a water tank heated by electrodes.
From the tank, steam is led into the cabinet through a pipe. The tank is
automatically filled from the water supply. The tank can be flushed by
switching the cabinet off at the main switch and then switching it
on again. In addition, the system is automatically flushed regularly
depending on water quality.
For further information on servicing and maintaining the humidifier,
please consult the "Service and operation manual". For maintenance of
the humidifier, request service assistance
GENERAL PRELIMINARY CHECKS
EN
7