Baker GA 950 / GA 550
Error message
Alarm high temperature
Alarm low temperature
Temperature
alarms
Condenser temperature high
Too many consecutive
evaporatör temperature
Room sensor error
Evaporator sensor error
Sensor alarms
Condenser sensor error
RF sensor error
Boiler overfilled – summon
service
Water connection error
Vapour system
Test water connection
alarms
Boiler discharge error
Boiler overfilled
Other alarms
Power connection error
alarms
Door open
Error Code
Description
The temperature around
the room sensor has been
E10
above the alarm value for
longer than the alarm
delay time
The temperature around
the room sensor has been
E11
below the alarm value for
longer than the alarm
delay time
The temperature around
the evaporatör sensor has
E8
been above the alarm
value for longer than the
alarm delay time
The evaporator
temperature alarm is
E7
occurring more frequently
than the setting for
repetition counts
Sensor defective, not
E0
connected or
shortcircuited.
Sensor defective, not
E1
connected or
shortcircuited.
Sensor defective, not
E2
connected or
shortcircuited
Sensor defective, not
E6
connected or
shortcircuited
Too much water in boiler,
E9
defective water valve.
No water connection to
E13
boiler, no power to water
valve.
No water connection to
E14, E32
boiler, no power to water
valve.
E15, E33
Defective water valve
E34
Defective water valve
Door open longer than 45
E12
min. or defective door
contact.
Loss of power for more
E35
than 5 min.
EN
System reaction
none
none
none
The compressor is
disconnected, and the
evaporator fan runs with
100% power.
Compressor runs for 5 min.
ON and 5 min. OFF.
Defrosting will be 45 min.,
and the evaporator fan will
start 10 min. after the
defrosting.
None
Vapour system will be shut
off until the error has been
remedied
Vapour system will be shut
off until the error has been
remedied
No steam production
No steam production
Vapour system will be shut
off until the error has been
remedied.
Vapour system will be shut
off until the error has been
remedied.
Compressor disconnected
until the error has been
remedied
Program is shut down
when the power comes
back on again.