AQUA SALT
Salt chlorine generator
8.5 TABS
The USER tab controls some operating parameters of your chlorine generator
Device state
Device state
Indicates the current state of the
device (Work, Boost, Mix, Start-up,
Backwash, Off).
Time left
Indicates the remaining time of the
current state, for Work, Boost, Mix
or Start-up.
Winter / Shutter
Indicates if Winter mode is on or
shutter is closed.
Phase
Phase
Indicates the current phase of the
device (Pause, Recirculation timer
Wait, Timer Wait, Flow Wait,
Flow stabilization, Work on, Work
off, Clean, backwash phases).
Time left
Indicates the time left for the
current
phase,
for
stabilization, Work on, Work off and
Clean.
Electrolytic cell
Chlorine set (%)
Indicates and sets the chlorine
percentage
to
be
generated.
Corresponds to the ratio between
ON time and cycle time, in case
other
compensations
such
temperature or UV are not involved.
Chlorine set during Winter Mode
(%)
Indicates and sets the chlorine
percentage to be generated during
Winter Mode. Corresponds to the
ratio between ON time and cycle
time, in case other compensations
such as temperature or UV are not
involved.
Chlorine generated (%)
Indicates the chlorine percentage
the
device
actually
generates,
compared to its maximum capacity.
It corresponds to the ratio between
ON time and cycle time.
Estimated
chlorine
generation
(g/h)
Indicates the amount of chlorine
generated in one hour. This amount
is an estimate.
Voltage (V)
Indicates the voltage at the two
extremities of the generator's cell.
Current (A)
Indicates
the
current
through the generator cell.
ADSP7000648
Last modification to the parameters
Last modification date
Indicates
the
modification to the parameters of the
device.
Pool
Pool type
Indicates the pool type (pool or SPA).
Analogue/digital inputs
Chlorine/Rx (ppm/mV)
Indicates the value of Chlorine or
Redox read by the respective probe, if
supported.
Chlorine/Rx Set Point (ppm/mV)
Indicates the value of Chlorine or
Flow
Redox Set Point.
pH
Indicates the pH value read by the
probe, if supported.
pH set point
Indicates the pH Set Point value.
as
pH level
Indicates if the level of pH corrector is
sufficient or insufficient.
Temperature (°C / °F)
Indicates the temperature read by the
probe.
Instant salinity (g/l/ppm)
Indicates the value of instant salinity.
This value is obtained from current,
voltage and temperature values.
Average salinity (g/l/ppm)
Indicates the value of average salinity.
Salinity Set Point (g/l / ppm)
passing
Indicates the Salinity Set Point value.
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
Flow
date
of
the
last
Indicates the state of the Absent Flow
alarm.
Recirculation pump state
Indicates
regarding the lack of power supply to
the recirculation pump
High temperature
Indicates
Temperature alarm.
Low temperature
Indicates
Temperature alarm.
Low production
Indicates
Production alarm.
Insufficient production
Indicates the state of the Insufficient
Production alarm.
Too much salt
Indicates the state of the Too Much Salt
alarm.
Ice
Indicates
"possible icing".
OFA Cl / Rx
Indicates the state of the "Chlorine or
Redox OFA" alarm, which goes off if
Chlorine or Redox values do not
increase as they should during the set
time.
pH OFA
Indicates the state of the "pH OFA"
alarm, which goes off if the pH value
does not change as it should during the
set time.
pH level
Indicates the state of the "Insufficient
pH level" alarm.
Salinity OFA
Indicates the state of the "Salinity OFA"
alarm, which goes off if the salinity
value does not increase as it should
during the set time.
Salinity level
Indicates the state of the "Insufficient
salinity level" alarm.
31/07/2017
ENGLISH
Alarms
the
state
of
the
alarm
the
state
of
the
High
the
state
of
the
Low
the
state
of
the
Low
the
state
of
the
alarm
101/264
101