AQUA SALT
Salt chlorine generator
Generator operation
Indicates the work mode of the
generator (Internal timers, External
timer, Proportional).
Polarisation time left
Indicates the remaining time of
current polarisation. At the end,
after the Clean interval, the polarity
of the voltage sent to the cell will be
switched.
Cycle time
Indicates the sum of ON and OFF
time.
Check cell
Indicates
the
time
left
checking the cell or running the
maintenance operations.
Cell replacement
Indicates
the
time
left
replacing the generator cell
 The PROGRAMMING/SETTINGS tab programmes and sets all the functionalities of the chlorine
generator.
Pool
Pool type
Indicates or sets the pool type (pool
or SPA).
Pool Capacity (cu. m / gal)
Indicates or sets the dimensions of
the pool.
Shutter Filter (hours)
Indicates or sets the duration of the
shutter filter, i.e. the time in which
chlorine generation must be kept
constant, although reduced.
Electrolytic cell
Chlorine set (%)
Indicates or sets the percentage of
Chlorine
to
be
generated,
compared
to
the
maximum
capacity. Corresponds to the ratio
between ON time and cycle time, in
case other compensations such as
temperature or UV are not involved.
Generator operation
Indicates or sets the work mode of
the chlorine generator (Internal
timers,
External
Proportional).
ADSP7000648
Salinity level
Indicates if the level of salinity is
sufficient or insufficient.
Flow
Indicates whether flow is present or not.
Shutter
Indicates if the shutter is open or
closed.
Recirculation pump relay state
before
Indicates if the relay of the recirculation
pump is open or closed.
Recirculation pump state
before
Indicates if the recirculation pump is on
or off.
Chlorine/Rx (Generator work mode:
Ppm max (ppm)
Indicates or sets the maximum Chlorine value
(depending on the type of chlorine probe you are
using).
Set point (ppm / mV)
Indicates or sets the value of Chlorine or Redox Set
Point.
Proportional range (ppm/mV)
Indicates or sets the value of Chlorine or Redox
proportional range.
Chlorine (Generator work mode: internal or
Temperature correction
Indicates or sets the state of correction according to
the temperature to apply to the chlorine percentage to
be generated (Yes, No).
UV correction
Indicates or sets the type of UV correction to apply to
the chlorine percentage to be generated (Off, Cold
timer,
shady, Cold Sunny, Mild shady, Mild Sunny, Tropical
shady, Tropical sunny)
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
Temperature sensor
Indicates the state of the "Temperature
sensor error" alarm.
Current
Indicates the state of the "Low current"
alarm.
Cell maintenance
Indicates it is necessary to check the
cell or to run the maintenance
operations.
Cell replacement early warning
Indicates that the generator cell will
soon need to be replaced.
Cell replacement
Indicates that it is necessary to replace
the cell of the generator.
proportional)
external timers)
31/07/2017
ENGLISH
States/phases
duration
Boost (hours)
Indicates
or
sets
the
duration of the Boost state.
Mixing (hours)
Indicates
or
sets
the
duration
of
the
Mixing
state.
Start-up (days)
Indicates
or
sets
the
duration of the Start-up
state.
Cycle time (minutes)
Indicates or sets the cycle
time of chlorine generation,
i.e. the sum of ON and
OFF time.
pH (probe
supported)
Set point
Indicates or sets the pH
Set Point value.
102/264