AQUA SALT
Salt chlorine generator
3.2.2
Installation
example
9. Installation example pH, Rx and ClJ models. It is advisable to enter the redox /
chlorine probe before the sand filter.
ID
A
Bipolar switches
B
Contactor to activate the circulation pump
C
Control relay of the contactor
D
Circulation pump operating feedback
E
External auxiliary activation
ADSP7000648
8 Connector overview. Lower part of the control box
The sample installation diagram below refers to the pH, pH/Rx, pH/ClJ models.
Description
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
Number 12 in picture 9 indicates the
electromagnetic
restoration. In order for the pump to
work correctly, it is necessary to
connect the level signal of the
product in the tank. Connect the
pump to the connector indicated with
PBr, and the level signal to the
connector indicated with LBr, both
shown in picture 8. Number 13 in
picture 9 indicates an external pump
to correct pH. If you want to use the
external pH pump, connect it to the
PPh connector, and connect the level
signal to the connector indicated with
LPh, shown in picture 8.
ID
Description
A
control system
1
QUA SALT
Electrolytic cell
2
Heat exchanger
3
Pool (max. capacity 200 cu. m)
4
Pool salt (NaCl)
5
Recirculation pump
6
Sand filter
7
Probes (pH, Redox)
8
pH corrector tank
9
Injection valves
10
Brine
11
Brine electromagnetic pump
12
pH electromagnetic pump
13
31/07/2017
ENGLISH
pump
for
brine
68
68/264