AQUA SALT
Salt chlorine generator
After every filter cleaning or every three months, we recommend to control the sate of the plates.
Every 500 hours of operation, the system warns the user to control the plates through the "Cell
Maintenance" alarm. The system is equipped with an automatic cleaning system that in most
cases is enough to maintain the cell in perfect conditions. In case of a particularly hard water
(rich in minerals) or if the chemical qualities of the water are unbalanced, the cell will require a
monthly cleaning.
Measure the pH value at least once a week to keep it controlled and to restore its value as quick
as possible. Check salinity and restore the correct value.
If you see significant limestones deposits in titanium plates you have to clean its with a specific
solution.Follow this procedure to reach this goal. Don't use brushes or other metal object to
remove deposits residue, they can damage plates covering reducing electrodes life and nullify
warranty. Pay attention to dont loose different o-ring that provide hydraulic sealing and avoid
water laeks. Leave plates in solution for two minutes. Repeat the steps below one more time if
you don't reach the desired results.
1.Switch off circulation pump and
close input and output valves in
eletrolitic cell system o.
5. Get off locking ring and o-ring
from tre cell.
9. In a bowl put 9 parts of water
and add 1 part of hydrochloric
acid so that fully dip titanium
plates in solution. Avoid to get in
contact brass electrodes with acid
solution prepared.
ADSP7000648
Monthly maintenance
Weekly maintenance
Electrolitic cell maintenance
2. Knock off flow sensor
cable and temperature probe
from
AQUASALT control
box
6.
Unscrew
the
three
electrodes with a tubular key
8 mm.
10.
After
cleaning
insert
plates in the cell slots.Go on
from right to left according to
this
sequence:
1
with
electrod – 5 simple – 1 with
electrod – 5 simple – 1 with
electrod.
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
3.
Unscrew
off
the
4. Unscrew two white rings
three
electrodes
of
from cell
cable with cap from
cell.
7.Lift electrodes
pullout.
8. Remove titanium plates.
Don't loose the three
Don't
o-ring you find inside.
locking baffler
11. Replace electrodes
12.
pullout
from
up
to
electrolitic cell and set it in
bottom. Be careful to
the system proceed from
don't pinch locking o-
point 6 to point 1 Screw
ring.
electrodes (point 6) until the
stop without force and check
to put again the three o-ring
in their sites
31/07/2017
ENGLISH
90
loose
electrodes
To
reassemble
90/264