AQUA SALT
Salt chlorine generator
S
UPERCHLORINATION KEY AND
Boost key activates superchlorination. The generator stops its internal adjustments and starts working at 100%, for a time
programmable up to 24 hours. At the end of the superchlorination process, the generator goes back to the set work mode.
Green LED steady on if superchlorination is active.
W
M
/S
INTER
ODE
HUTTER KEY AND
This key allows you to manually activate the Winter mode, which reduces chlorine generation by 15% minimum (within a
programmable range from -15% to -100%). The corresponding red LED is:
steady if winter mode is active;
flashing if covering shutter is detected.
A
L
: Red steady Led on, if an alarm not included within those indicated by the Maintenance led goes off (see Alarms
LARM
ED
section);
M
L
: Red steady Led on, if Maintenance Cell or Cell Replacement early-warning/alarm go off;
AINTENANCE
ED
In order to check the parameters of the pool and to control the correct operation of chlorine generators,
4.1
you can access menus, submenus and sections using the keypad keys as shown above. We are
showing below an overview of the menus available and how to switch from one to the other when you are
The Menus
in one of their sections. A detailed explanation of the various menus and sections is also provided. The
picture below shows the three menus available, and how to switch from one to the other.
1) Some sections of the menus belong to certain models and/or working modes and/or states or phases of the device, and
will be visualized only if the device is set to show them. More in detail:
1.1) Sections related to the pH will be present only if the chlorine generator is equipped with a pH probe
1.2) Values expressed in ppm are present only if working mode is "proportional" and the device is a "pH/Chlorine" model.
1.3) Values expressed in mV are present only if working mode is "proportional" and the device is a "pH/Rx" model.
2) If keys
are close to the sections, the values can be modified, otherwise they are read-only.
3) Press F to switch from a section to the following one.
4) The units of measurement of the parameters can be chosen in the System Settings Menu.
The User Menu visualizes information regarding the system and some pool parameters. The AQUA_SALT
4.2
display goes back to the main section of this menu if you do not press any key on the user interface during
more than two minutes.
User
Press and hold F for 3 seconds to switch to the Programme Start Menu.
Menu
Press and hold Enter for 1 second to access the Password Menu
The sections marked with * can be visualized also when the device is Off.
The User Menu visualizes the following sections:
ADSP7000648
L
:
ED
L
:
ED
Installation
Menu
General instructions to use the menus:
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
User Menu
Enter
for about
1 sec
Password
Menu
31/07/2017
ENGLISH
71
71/264