Current Alarm - Aqua SALT Cella 50 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AQUA SALT
Salt chlorine generator
The current alarm can be enabled/disabled from the Alarms Menu, under "Current alarm", selecting On/Off
5.11
The alarm goes off when a current value below 1 A is recorded, for a voltage that is higher than half the
maximum voltage set for the generator.
Current
alarm
Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
Red alarm LED steady on;
"Current Alarm" flashing on the display;
Current alarms may be caused by the absence of salt in the water, or by low salt. If low salt alarm is enabled,
it will go off as well. Check that the electrolytic cell is supplied and connected to the electric system.
The alarm automatically resets when it records a current level above the threshold, for the given voltage.
ADSP7000648
The device indicates
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
31/07/2017
ENGLISH
88
88/264

Publicidad

Tabla de contenido
loading

Productos relacionados para Aqua SALT Cella 50

Este manual también es adecuado para:

Salt cella 100Salt cella 150Salt cella 200

Tabla de contenido