AQUA SALT
Salt chlorine generator
The current alarm can be enabled/disabled from the Alarms Menu, under "Current alarm", selecting On/Off
5.11
The alarm goes off when a current value below 1 A is recorded, for a voltage that is higher than half the
maximum voltage set for the generator.
Current
alarm
Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
Red alarm LED steady on;
"Current Alarm" flashing on the display;
Current alarms may be caused by the absence of salt in the water, or by low salt. If low salt alarm is enabled,
it will go off as well. Check that the electrolytic cell is supplied and connected to the electric system.
The alarm automatically resets when it records a current level above the threshold, for the given voltage.