AQUA SALT
Salt chlorine generator
When chlorine generator is activated for the first time and the pool contains water without chlorine, we
3.5
recommend to run the Boost mode. This operating mode performs a shock chlorination, producing
chlorine at its maximum capacity for a maximum of 24 hours. At the end of the Boost programme, it is
System
possible to activate the Start-up phase, which runs the automatic cleaning cycle every 2 hours for a
activation
programmable period (15 days by default). At the end of the start-up time, the cleaning cycle is set to run
every 4 hours. This provides a more frequent cleaning during the first period. Frequency then decreases
to ensure a longer useful life to the cell. The daily chlorine production must be set as a function of the
number of bathers, depending on the water temperature and size of the pool (with the exception of the
proportional operation mode). To activate the chlorine generator, it is necessary to adapt the following
parameters to the configuration of your system:
Cell type: insert the capacity value of your pool's cell (50, 100, 150, 200).
Pool capacity: insert the volume (cu. m) of your pool
Operating mode: choose how to operate the chlorine generator (external timer, internal timer, proportional,
see the opening pages of the manual).
4 Programming
procedure
Up/Down keys modify the numerical values for every menu section and scroll the options of the
sections.
Enter (ENT) key accesses and exits the submenu sections. By holding it for 1 second from the User
Menu, you will access the Installer Menu. If you hold it from the main sections of a Menu, you will go
back to the parent Menu.
Function (F) scrolls the sections of the Menus.
Press it for 1 second from the User Menu to access the Programme Start Menu.
C
P
-
/S
HLORINATION
OWER
ON
TATE KEY AND LED
Pressing the ON / OFF button enables the production of chlorine, the next press production is disabled.
When the production of chlorine is enabled, the LED is:
Green steady: chlorine production enabled but not running at the moment of viewing;
flashing green: chlorine production enabled and running.
When the chlorine production is disabled the LED is off.
ADSP7000648
To get the best results
its activity and set the values of its parameters. To do so, the system
comes with a user interface equipped with:
Display
Keys
Led
The system can be also programmed through a software you can
install on your Windows PC.
Picture 9 shows the user interface. We will now see its main
characteristics.
:
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
from your chlorine generator, programme
User Menu
Start
Program
Menu
31/07/2017
ENGLISH
70
70/264