High/Low Temperature And Ice Alarm; Flow Alarm; Ph Level Alarm - Aqua SALT Cella 50 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AQUA SALT
Salt chlorine generator
1) The High temperature alarm, which cannot be disabled from the alarms menu, goes off if
5.2
temperature read is higher than 60 °C.
High/low
temperature and
ice alarm
During the alarm, the generator stops working.
The alarm is automatically reset when the probe reads a temperature value below 60 °C.
2) The Low temperature alarm, which cannot be disabled from the Alarm menu, goes off if
temperature goes below 5 °C.
3) In case the temperature read by the probe goes below 2,5 °C and the ice alarm was enabled
from the Alarms menu, it will activate as well, together with the Low temperature Alarm.
The ice alarm is reset when the alarm is disabled from the Alarms Menu. It is automatically reset
when the probe reads a temperature above 2,5°C. The Low temperature alarm is reset when the
values read are above 5 °C.
The flow alarm, which cannot be disabled, goes off whenever the generator is operating, but water
5.3
flow is absent.

Flow alarm

When this alarm goes off, the generator stops working.
The alarm will be automatically reset as soon as water flow resumes in the electrolytic cell.
The flow sensor input has a recognition filter that lasts about 10 seconds to prevent false contacts
and undesired false alarms.
The pH level alarm can be enabled/disabled from the Alarms Menu selecting On/Off, only in the
5.4
models equipped with the pH corrector pump and its probe (pH or pH/ClJ or pH/Rx Models). In this
case, in the inputs set of the chlorine generator there will be also a level input to control the presence of

pH level alarm

the pH corrector in the tank where the suction pipe of the pump is dipped.
The input has a recognition filter that lasts 3 seconds, to prevent false contacts and undesired false
alarms.
The alarm automatically resets when the level of chemical to be dosed is restored. You can reset it
from the Alarms Menu, selecting Off.
ADSP7000648
Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
Red alarm LED steady on;
"High temperature Alarm" flashing on the display;
Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
Red alarm LED steady on;
"Low temperature Alarm" flashing on the display;
Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
Red alarm LED steady on;
"Ice Alarm" flashing on the display;
The device indicates:
Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
Red alarm LED steady on;
"Flow Alarm" flashing on the display;
Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
Red alarm LED steady on;
"pH level Alarm" flashing on the display;
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
The device indicates:
The device indicates:
The device indicates:
The device indicates: