AQUA SALT
Salt chlorine generator
This section outlines the procedure to quickly programme the generator in case it comes equipped with a pH
probe and a pump to restore the correct pH value. We recommend to first calibrate the probe following the
procedure you can find at paragraph 4.5.5 of this Manual.
AQUA SALT KEYPAD
1
Switch on or off your AQUA SALT with the ON/OFF key.
Press and hold Enter You will switch to the Password Menu
2
Default password: 0000 Press and hold Enter You will switch to the Installer Menu
3
Press F to scroll the Menu down to Pool Settings Press Enter to access the submenu
4
5
Press F to scroll down to Pool Capacity
6
Insert the capacity of your pool using UP or Down
7
Press F to confirm and move to Generator Operation
8
Scroll with UP or Down and select the desired operating mode
9
Press and hold Enter to save the modifications and go back to the Installer Menu
Press F to scroll down to System Settings Press Enter to access the submenu
10
11
Press F to scroll down to Cell Type
12
Select the dimensions of the installed cells using UP or Down
13
Press and hold Enter to save the modifications and go back to the Installer Menu
14
Press Enter to access the submenu
Press F to scroll down to Programming Press Enter to access the submenu
15
16
Press F to scroll down to pH Set Point
17
Insert the desired value with UP and Down (standard values 6.8-7.2)
18
Press F to switch to the Ph Work Mode Menu
19
Use UP or Down to scroll and select Acid or Alkaline Mode
20
Press F to switch to the following menu line: pH proportion range
21
Scroll with UP or Down and select the desired operating mode
22
Press F to switch to pH Cycle Period
23
Use Up and Down to select the minutes for the pH cycle period
24
Press and hold Enter to save the modifications and go back to the Installer Menu
25
Press and hold Enter to go back to the User Menu
ADSP7000648
AQUA SALT - with pH probe operating mode
set point= 7, operating mode=alkaline, cycle time= 15 minutes
pH proportional range=0.5, pH from the probe= 6
The pump cyclically doses the pH corrector during the whole
cycle time, until the pH level is below 6.5. Once this value is
reached, it calculates a dosing time that is proportional to the
difference between the set point and the value read by the
probe. The dosing time gradually decreases as the difference
between these values does, until the set point is reached.
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
EXAMPLE
EXPLANATION
31/07/2017
ENGLISH
56