Backwash Start Menu - Aqua SALT Cella 50 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AQUA SALT
Salt chlorine generator
This section is shown only in case the device is already in one of the following phases:
Boost
Mixing
Start-up
Interrupt phase
Off
and their interruption is required before starting another programme. This value is visualized for 3
seconds, then the device automatically goes back to the main section of the User Menu
If you want to activate Backwash, press Enter when this section is visualized and access the menu of
Start backwash
the Backwash procedure.
Once you activate Mixing by confirming the request, you will be sent back to the time left section of the
Start mixing
User Menu. From that section, it is possible to interrupt Mixing if required.
Once you start the Start-up phase by confirming the request, you will be sent back to the time left
Start-up
activation
section of the User Menu. From that section, it is possible to interrupt the Start-up, if required.
To start the Backwash, follow the procedure visualized on the display and described below (steps
4.3.1
1-7)
Backwash Start
Menu
1
2
3
4
5
6
7
At the end of the procedure, you will be sent back to the Backwash Start on the Programme Start
menu.
ADSP7000648
Interrupt phase
Start-up activation
Confirm? Yes/No
Enter
Start Backwash
Start-up
activation
Confirm? Yes/No
Start mixing
Press Enter to switch to the following menu section.
Press and hold Enter for about 1 second to go back to the Backwash Start section of the
Programme Start Menu.
Set the multivalve on Backwash and press Enter.
Activate the pump for a time programmable with keys
The system starts a countdown and activates the recirculation pump for the duration set at
point 2.
Set the multivalve on rinse and press Enter
Activate the pump for a time programmable with keys
The system starts a countdown and activates the recirculation pump for the duration set at
point 5.
Set the multivalve on Filter and press Enter.
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
Enter
Menu
Start backwash
Start mixing
Enter
31/07/2017
from 0 to 5 minutes.
from 0 to 60 seconds
ENGLISH