Aqua SALT Cella 50 Manual De Instrucciones página 92

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AQUA SALT
Salt chlorine generator
Below you can see the diagram of the electrolytic cell and its components, together with a table
7.2
of the codes required to order the parts to be replaced in case of breaking
Annex B
Dimensions
N
Code
1
ADSP6002140
ADSP6002150
2
ADSP6002330
ADSP6002340
PTESL050106M
PTESL100107M
3
PTESL150108M
PTESL200109M
PTEPL050102M
PTEPL100103M
4
PTEPL150104M
PTEPL200105M
5
ADSP6002190
6
ADSP6002470G
7
MG010370
ADSP6002201
ADSP6002202
8
ADSP6000812
ADSP6000713
9
ADSP6002210
10
ADSP6002220
11
ADSP6002230
12
ADSP6002247
13
ADSP6002300
14
A6010660
7.3
The default parameters are the values that have been assigned to parameters and
variable during the development of the system and that you can restore from the System
Annex C Default
Setup menu to "restore default settings"
Parameters
Chlorine content: 100%; Percentage of chlorine in Winter Mode: 85%; Polarization time: 4 hours; Mixing time: 12 hours;
Days of Startups: 15 days; Cycle time: 15 minutes; Set point chlorine: 1.00 ppm; band proportionality of chlorine: 0.5 ppm;
set point pH: 7.2; way of working pH: acid; band proportionality pH: 1.0; cycle period of pH: 5 minutes; set point salinity: 4.0
g / l; band proportionality salinity: 1.5 g / l; cycle period salinity 150 minutes; chlorine temperature correction: yes; Chlorine
UV correction: off; Internal timers: off; tank capacity: 100; generator operation: external timer; filter flow: 10 seconds; filter
shutter: 3 hours
ADSP7000648
Description
AQUA SALT CELL PIPE
PARTITION FOR ELECTRODE BLOCK L50-150
PARTITION FOR ELECTRODE BLOCK L100
PARTITION FOR ELECTRODE BLOCK L200
TITANIUM PLATE NORMAL ELECTRODE L50
TITANIUM PLATE NORMAL ELECTRODE L100
TITANIUM PLATE NORMAL ELECTRODE L150
TITANIUM PLATE NORMAL ELECTRODE L200
TITANIUM PLATE CONTACT ELECTRODE L50
TITANIUM PLATE CONTACT ELECTRODE L100
TITANIUM PLATE CONTACT ELECTRODE L150
TITANIUM PLATE CONTACT ELECTRODE L200
ORM-0500-20 50x2
AQUA SALT CELL ELECTRODE HOLDER INSERT GREY WITH PROBE
PT100
OR - REF. 2015 – NBR
CHLORINE GENERATOR CONTACT PIN - AISI 316 M3
CHLORINE GENERATOR CONTACT PIN - AISI 316 M4
SCREW M 4 X 8 UNI 7687 (TCTC) INOX A2
SCREW M 3 X 8 UNI 7687 (TCTC) INOX A2
LOCKING RING FOR AQUA SALT PLATES
AQUA SALT CELL CLOSING RING
OR - REF. 6325 – NBR
AQUA SALT RESIN-COATED FLOW SENSOR UNIT WITH REED
AQUA SALT D60 PIPE REDUCTION
WHITE FP3 RING NUT
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
31/07/2017
ENGLISH
92
92/264

Publicidad

Tabla de contenido
loading

Productos relacionados para Aqua SALT Cella 50

Este manual también es adecuado para:

Salt cella 100Salt cella 150Salt cella 200

Tabla de contenido