Recirculation Timer Menu - Aqua SALT Cella 50 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AQUA SALT
Salt chlorine generator
pH set point
Visualize and change the
value set for the pH set point
choosing among 5.0... .9.0.
Item only appears if the
control
unit
includes
the
presence of the pH probe.
Salinity set point
Visualize and change the
value set for the salinity set
point
choosing
between
0.0...5.0 g/l or 0...5000 ppm
Polarisation
Visualize and change the
value set for the polarisation
period from 1 to 16 hours.
To learn what Polarisation is,
see par. 2.2
The Recirculation Timer Menu enables and programs 12 timers from 0 to 24 h, which can be disabled one
4.5.7
by one or all together and regulate the recirculation pump, enabling chlorine generator's operation. For each
Recirculation
timer Menu
timer, identified by the codes R01...R12 it is necessary to set type, start time and duration.
Press and hold Enter for one second to go back to the "Recirculation Timer" of the Installer Menu.
For the sections "Timer N start" and "Timer N duration" press Enter to confirm the hours and
minutes and move to the following section.
Recirculation
timers enabled
Timer type
Timer start
ADSP7000648
pH work mode
Visualize and change the
value set for the pH work
mode
choosing
between
acid or alkaline.
Item only appears if the
control
unit
includes
the
presence of the pH probe.
Salinity proportional
range
Visualize and change the set
value
for
the
salinity
proportional range, choosing
among 0.5/1/1.5/ 3 g/l or
among 500/1000/1500/3000
ppm
Mixing
Visualize and change the
value set for the Mixing
period from 1 to 20 hours.
To learn what Mixing work
mode is, see par. 2.3
Recirculation
timers enabled
Timer
duration
Timer Start
It enables or disables the 12 recirculation timers choosing On or Off.
Disables each timer individually by setting it to Off or allows to choose the type of timer
among Mon-Fri (works from Monday to Friday), Sat-Sun (works on Saturdays and
Sundays only), Mon-Sun (works continuously from Monday to Sunday).
Sets the start time of each timer with the format HH:MM.
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
pH proportional
range
Visualize and change the
value
set
for
the
pH
choosing
proportional
range
among 0.5 / 1/ 1.5/ 3.
Item only appears if the
control
unit
includes
the
presence of the pH probe.
Salinity cycle
period
Visualizes and changes the
set value for the salinity cycle
at intervals of 5, from a
minimum duration of 30 and
a maximum of 300 minutes
Start-up
Visualize and change the
value set for the Boost period
from 1 to 99 days. To learn
what start-up programme is,
see par. 2.3
timer type
31/07/2017
ENGLISH
pH cycle period
Visualizes and modifies the
value set for the chlorine set-
point at intervals of 5, for pH
cycle period, from a minimum
of 5 and a maximum of 120
minutes.
Item only appears if the
control
unit
includes
the
presence of the pH probe.
Boost
Visualize and change the
value set for the Boost period
from 1 to 24 hours. To learn
what a Boost work mode is,
see par. 2.3
Cycle time
Visualize and change the
value set for the cycle period,
from 15 minutes minimum to
5 hours maximum at
intervals of 15 minutes.
81/264