There are 3 types of production/salinity related alarms. The table below shows the thresholds of the
5.5
alarms, according to the dimensions of the titanium plates of the cell.
1.
Salt/production
alarms
The too much salt alarm is automatically reset when the voltage rises above the permitted
threshold. You can reset it from the Alarms Menu, selecting Off.
2.
Reduced production alarm automatically resets when the current level is higher than the
threshold. You can reset it from the Alarms Menu, selecting Off.
3.
Insufficient production alarm automatically resets when the current level is higher than the
threshold. You can reset it from the Alarms Menu, selecting Off.
ADSP7000648
Excessive salt alarm, enabled/disabled under "Excessive salt Alarm." in the Alarms Menu.
This alarm is activated if the cell is in operation and the voltage drops below 20V.
Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
Red alarm LED steady on;
"Excessive salt Alarm" flashing on the display;
Reduced production alarm, can be enabled/disabled under "Reduced production Alarm" in
the Alarms Menu. This alarm is triggered if the cell in operation, and the current is below the
threshold indicated in the table below. In case the insufficient production Alarm is not
enabled from the Alarms Menu, the Reduce production Alarm is activated for even lower
values.
Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
Red alarm LED steady on;
"Reduced production Alarm" and "Check salt concentration and cell cleaning"
flashing on the display;
Insufficient production alarm, enabled/disabled under "Insufficient production Alarm." in
the Alarms Menu. This alarm is triggered if the cell in operation, and the current is below the
threshold indicated in the table below.
Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
Red alarm LED steady on;
"Insufficient production Alarm" and "Check salt concentration and cell cleaning"
flashing on the display;
Insufficient
production alarm
threshold (A)
Cell 50
Cell 100
Cell 150
Cell 200
Alarm salinity/production thresholds
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
The device indicates:
The device indicates:
The device indicates:
Reduced production
alarm threshold (A)
1.25
2.0
2.50
3.5
3.50
5.0
5.00
7.0
31/07/2017
ENGLISH
Excessive salt alarm
threshold (V)
20
20
20
20
86/264
86