The hardware items and mounting methods shown in this figure are just a few of the
mounting options for the control cabinet. If using a mounting configuration that is different
than that shown, make sure hardware is of sufficient size and quality to support the control
cabinet.
Key for Figure 4-4 (items not included in the scope of supply):
Wall-mounted
1
Hexagonal head lag bolt, length as required
2
Retaining washer
3
Flat washer
4
Hexagonal head machine bolt, length as required
5
Hexagonal nut
Pole-mounted
6
Mounting pole/pipe
4.7

Ground solar system

The negative pole [–] of the battery must be connected to earth ground. On the bottom
(lower shelf) of the control cabinet you will find a grounding terminal (see Figure 4-5). All
chassis grounds are channeled through this terminal.
The solar system must be grounded in accordance with the national regulations. We
2
recommend using a 16 mm
Key for Figure 4-5:
1
Lower shelf of the control cabinet
2
Earth ground connection
3
Earth-ground wire lug, 16 mm
supply)
4
Nut (1 x)
5
Functional earth ground (FE), cable 16 mm
grounding cable (not included in the scope of supply).
2
for M6 threaded bolts (not included in the scope of
2
(not included in the scope of supply)
Installation
4-9