RAD-SOL-SET-24-...
Charge controller RAD-SOL-CHG-24-10
System voltage
Nominal input current from the solar system
Nominal load
Load disconnection (low voltage disconnection)
Restart following low voltage disconnection
Temperature compensation at 25 °C
Current consumption
Permissible temperature range
Solar panel RAD-SOL-PAN-12-50
Power
Tolerance
Voltage at the point of maximum output
Current at the point of maximum output
Non-load voltage
Short-circuit current
Ambient temperature range
Dimensions (W x H x D)
Standard
Alternative
Weight
Determination of electrical values for a solar panel is carried out under standard test conditions (STC) with an irradiance of 1000 W/m², an air
mass (AM) of 15 and a cell temperature of 25 °C.
Battery RAD-SOL-BAT-12-40
Nominal voltage
End-of-charge voltage
Capacity
Design
Ambient temperature
Dimensions (W x H x D)
Weight
Battery RAD-SOL-BAT-12-100
Nominal voltage
End-of-charge voltage
Capacity
Design
Ambient temperature
Dimensions (W x H x D)
Weight
10-2
PHOENIX CONTACT
24 V DC
10 A
10 A
23 V DC
25.2 V DC
–56 mV/K
6 mA .... 10 mA
-40 °C .... +85 °C
50 W
P
+10 % / -5 %
17.9 V DC
2.8 A
22.1 V DC
3.07 A
–20 °C ... +85 °C
706 mm x 744 mm x 36 mm
537 mm x 839 mm x 50 mm
6.5 kg, approximately
12 V DC
13,8 V DC ... 14,4 V DC
40 Ah
Gelled electrolyte
–20°C ... +55°C
175 mm x 175 mm x 210 mm
15 Kg
12 V DC
13,8 V DC ... 14,4 V DC
100 Ah
Gelled electrolyte
–20°C ... +50°C
306 mm x168 mm x 211 mm
29,3 Kg