FinishPro II 595 Error Codes

FinishPro II 595 Error Codes
INJECTION HAZARD
• Keep a new transducer on hand to use for test.
• No display does not mean the sprayer is not
pressurized. Before repair, Relieve Pressure,
page 28.
Display
No Display
Sprayer stops. Power is not
applied. Sprayer may be
pressurized.
psi/bar/MPa
Sprayer is pressurized. Power is
applied. (Pressure varies with tip
size and pressure control setting.)
E=02
Sprayer may continue to run.
Power is applied.
E=03
Sprayer shuts down and LED
continues to blink three times
repeatedly. Power is applied.
E=04
Sprayer shuts down and LED
continues to blink four times
repeatedly. Power is applied.
E=05
Sprayer does not start or stops and
LED continues to blink five times
repeatedly. Power is applied.
E=06
Sprayer stops and LED blinks six
times repeatedly. Power is applied.
- - - -
Power is applied.
EMPTY
Sprayer stops. Power is applied.
E=10
Sprayer does not start or stops and
LED continues to blink 10 times
repeatedly. Power is applied.
50
Sprayer Operation
NOTE: Do not allow sprayer to develop fluid pressure
without transducer installed. Leave prime valve open if
test transducer is used.
1. For sprayers with digital display, see Digital display
Messages.
2. Remove screws (12) and cover (50).
3. Turn ON/OFF switch ON.
4. Observe LED operation and reference following
table:
Indicates
Loss of power.
Check power source. Relieve pressure
before repair or disassembly.
Normal operation.
Do nothing
Runaway pressure.
Replace motor control board or pressure
Pressure greater than
transducer.
4500 psi (310 bar, 31
MPa) or damaged
pressure transducer
Pressure transducer is
Check transducer connection. Open drain
faulty or missing.
valve. Substitute new transducer for
transducer in sprayer. If sprayer runs,
replace transducer.
Line voltage is too high.
Check for voltage supply problems.
Motor fault.
Check for locked rotor, shorted wiring or
disconnected motor. Repair or replace
failed parts.
Motor is too hot or there
Allow sprayer to cool. If sprayer runs
is a fault in motor thermal
correctly when cool, check motor fan
device.
function and air flow. Keep sprayer in cool
location. If sprayer does not run when cool
and continues to blink six times, replace
motor.
Pressure is less than 200
Increase pressure if desired. Drain valve
psi (14 bar, 1.4 MPa)
may be open.
Empty paint pail. Loss of
Refill paint pail. Check for leaks or clogged
pressure.
pump inlet. Repeat Startup procedure.
High control board
temperature.
What To Do
Make sure motor air intake is not
blocked.
Make sure control board is properly
connected to the back plate and that
conductive thermal paste is used on
the power components.